Reference: S6GR1P3KM

Brand: Solis

Solis S6-GR1P3K-M 3kW Single Phase Mini Inverter

(0)
String inverter of the Solis-Mini S6-GR1P3KM Single phase 3kW, suitable for green energy in small residential and commercial rooftops, and adopts full digital control technology, advanced topological structure and accurate MPPT algorithm, whose efficiency is higher than the Industry leading conversion which is up to 97.3% maximum.
€432.00 €720.00
More
In Stock
All best sellers
  • PayPal

  • On sale!
  • Reduced price
Victron Cyrix-ct 12/24V-120A Intelligent battery combiner
  • Victron Cyrix-ct 12/24V-120A Intelligent battery combiner
  • Victron Cyrix-ct 12/24V-120A Intelligent battery combiner
  • Victron Cyrix-ct 12/24V-120A Intelligent battery combiner
  • Victron Cyrix-ct 12/24V-120A Intelligent battery combiner
  • Victron Cyrix-ct 12/24V-120A Intelligent battery combiner
  • Victron Cyrix-ct 12/24V-120A Intelligent battery combiner

Victron Cyrix-ct 12/24V-120A Intelligent battery combiner

OF009285

Victron Cyrix-ct 12/24V-120A intelligent battery monitoring to prevent unwanted switching, 46x46x80mm, 0.11kg.

€55.68
€44.54 Save 20%
VAT excluded
Ships within 8-10 working days from EU warehouse

Select VAT rate according to your needs. If you select 10% VAT you must send the signed declaration otherwise we will not be able to ship the goods. Only for shipments to Italy.


* SELEZIONA IVA

Quantity
In Stock

Description

Victron Cyrix-ct 12|24V-120A Intelligent battery combiner

Intelligent battery monitoring to prevent unwanted switching
Some battery combiners (also called voltage controlled relay, or split charge relay) will disconnect a battery in case of a short but high amperage load. A battery combiner also may fail to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value once the batteries are connected.
The software of the Cyrix-ct 12/24 does more than simply connect and disconnect based on battery voltage and with a fixed time delay. The Cyrix-ct 12/24 looks at the general trend (voltage increasing or decreasing) and reverses a previous action only if the trend has reversed during a certain period of time. The time delay depends on the voltage deviation from the trend. (for Battery Combiners with multiple engage/disengage profiles, please see the Cyrix-i 400).
Long bolts to allow connection of more than one power cable
Cyrix 12/24-120: 13 mm (M6)
Cyrix 12/24-230: 16 mm (M8)
Protection against overheating (due to a long duration overload e.g.)
The Cyrix will disengage in case of excessive contact temperature, and reengage again after it has cooled down.
LED status indication (Cyrix 12/24 230 only)
LED on: engaged
LED 10 s flash: disengaged
LED 2 s flash: connecting
LED 2 s blink: disconnecting
LED 0,25 s blink: alarm (over temperature; voltage > 16 V; both batteries < 10 V; one battery < 2 V) (multiply by two for 24 V)
12/24 V auto ranging
The Cyrix-ct 12/24 automatically detects system voltage.
No voltage loss
Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.
Prioritising the starter battery
In a typical setup the alternator is directly connected to the starter battery. The accessory battery, and possibly also a bow thruster and other batteries are each connected to the starter battery with Cyrix battery combiners. When a Cyrix senses that the starter battery has reached the connect voltage it will engage, to allow for parallel charging of the other batteries.
Bidirectional voltage sensing and power supply from both batteries
The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory battery is being charged by a battery charger.
The Cyrix-ct 12/24 has a dual power supply. It will therefore also close if the voltage on one battery is too low to operate the Cyrix.
In order to prevent unexpected operation during installation or when one battery has been disconnected, the Cyrix-ct 12/24 will not close if the voltage on one of the two battery connections is lower than 2 V (12 V battery) or 4 V (24 V battery).
Parallel connection in case of emergency (Start Assist)
The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30 seconds) or a switch to connect batteries in parallel manually. This is especially useful in case of emergency when the starter battery is discharged or damaged.

Features:
Model: Cyrix-ct 12/24V-120A;
Status LED: No;
Continuous current: 120A;
Starting speed (5 seconds): 180A;
Connection voltage: 13V to 13.8V and 26V to 27.6V
with intelligent trend detection;
Disconnection voltage: 11V to 12.8V and 22V to 25.7V with intelligent trend detection;
Current consumption when open: <4mA;
Current consumption when closed: 12V - 220mA | 24V - 120mA;
StartAssist: Yes (Cyrix stays active for 30 seconds);
Control cable included (1m length): No;
Protection category: IP54;
Weight: 0.11 kg (0.24 lbs);
Dimensions HxWxD: 46x46x80 mm (1.8 x 1.8 x 3.2 inches).

Product Details
OF009285

Specific References

EAN13
8719076022145
MPN
OF009285
Comments (0)
Grade
No customer reviews for the moment.
10 other products in the same category:

Follow us on Facebook